#TrainingTuesday  

To help bring the classroom to installers, wherever you are, our trainers have made short videos on a range of topics from servicing, maintenance to installation and repairs to share on our social media channels.

Catch up on our weekly #TrainingTuesday videos

Every Tuesday at 12 noon, one of our knowledgeable trainers will be sharing their top tips and advice, and at no more than a minute long, even the busiest installer can find time to watch.

For nuggets of wisdom to make working on your favourite boilers even easier, follow us on our social channels:

Don't do social media? Check back here each Tuesday for a new video.

Of course, there's no substitute for getting hands on and 'learning by doing', so if you like what you see and want to learn more, book on to one of our free product training or specialist training days at our centres throughout the UK.

This video is intended for Gas Safe registered engineers only and is subject to our full video disclaimer which can be found here.

Latest video:

Richard Green shows you how to check a gas valve with a multimeter

{ Enter Video Library Header Text Here }

{ Enter Video Library Introductory Text Here }
Get experts tips every week from Baxi in the #TrainingTuesday video series

How to test a boiler gas valve with a multimeter

Richard Green shows you how to check a gas valve with a multimeter

Get experts tips every week from Baxi in the #TrainingTuesday video series

How to test thermistors in perfect and imperfect scenarios

Richard Green shows you how to test thermistors in perfect and imperfect scenarios

Get experts tips every week from Baxi in the #TrainingTuesday video series

How to turn a Grundfos UPM3 pump when clogged with debris

Richard Green talks about Grundfos UPM3 pumps and shows you how they can be turned in the event of being clogged with debris

Get experts tips every week from Baxi in the #TrainingTuesday video series

How to check the gas inlet working pressure (Error code E133)

Checking the gas inlet working pressure in relation to error code E133, demonstrated on a Baxi 600

Get experts tips every week from Baxi in the #TrainingTuesday video series

A handy feature on Baxi 600 when changing potentially wet components

Dave Driver demonstrates a handy feature on Baxi 600 when changing any potentially wet components

Get experts tips every week from Baxi in the #TrainingTuesday video series

How to check ignition on the Baxi Duo-tec and Baxi Platinum boilers

Dave Driver demonstrates a helpful check you can make to prove ignition on the Baxi Duo-tec and Baxi Platinum boilers even when E133 is displayed and the flame symbol is not illuminated

Get experts tips every week from Baxi in the #TrainingTuesday video series

How to not lose the injector when removing the gas/air unit

James Hodgson shows you how to 'not' lose the injector when removing the gas/air unit from Baxi Duo-tec and Baxi Platinum boilers

Get experts tips every week from Baxi in the #TrainingTuesday video series

How to remove the lip seal from the hydraulic block

James Hodgson shows you how to easily remove the lip seal from the hydraulic block on the Baxi Duo-tec and Baxi Platinum boilers

Get experts tips every week from Baxi in the #TrainingTuesday video series

Introducing the Information Mode on the Baxi Duo-tec and Platinum boilers

Roy Fugler gives you an introduction to Information Mode explaining the different functions and how you we might use them on the Baxi Duo-tec and Baxi Platinum boilers

Get experts tips every week from Baxi in the #TrainingTuesday video series

How to recognise a zone valve that can be taken apart

Rob Evans takes you through how to recognise a zone valve that can be taken apart Vs one that can't, saving you time and money when conducting work on a system

Get experts tips every week from Baxi in the #TrainingTuesday video series

How to check the output from the spark generator 

Rob Evans shows you a handy tool for checking output from the spark generator on the Baxi Duo-tec and Baxi Platinum boilers

Get experts tips every week from Baxi in the #TrainingTuesday video series

How to do a flue integrity check

Rob Evans demonstrates how to do a flue integrity check on the Baxi Solo heat only boiler

Get experts tips every week from Baxi in the #TrainingTuesday video series

The effects of weather compensation 

Ian Trott explains the effects of weather compensation and setting the curve setting on a Baxi 600 boiler

Get experts tips every week from Baxi in the #TrainingTuesday video series

How to check the fans on the Baxi Heat only range

How to check if the fan is going on the Baxi Heat only range of boilers

Get experts tips every week from Baxi in the #TrainingTuesday video series

How to detect a leak in the Schrader valve

How to detect if the expansion vessel Schrader valve is leaking and how to replace it

Get experts tips every week from Baxi in the #TrainingTuesday video series

How to deal with a persistent system pressure loss fault

Persistent system pressure loss fault

Get experts tips every week from Baxi in the #TrainingTuesday video series

How to re-pressurise the expansion vessel

The correct procedure for re-pressurising the expansion vessel

Get experts tips every week from Baxi in the #TrainingTuesday video series

How to put the Baxi 600 Combi into the service function

Top tip on how you put the Baxi 600 Combi into the service function (commonly know as the chimney sweep mode) and how you would keep the boiler cool if all the radiators were already hot

Get experts tips every week from Baxi in the #TrainingTuesday video series

Boiler connections on the Baxi 600 Combi

The boiler connections on the Baxi 600 Combi

Get experts tips every week from Baxi in the #TrainingTuesday video series

How to test the hall affect sensor without a multimeter

Top tip on how you can test the hall affect sensor without a multimeter on the Baxi Duo-tec and Baxi Platinum Combi ranges

Get experts tips every week from Baxi in the #TrainingTuesday video series

How to check the pump for circulation on Baxi Duo-tec and Platinum Combi

Top tip when checking the pump for circulation on the Baxi Duo-tec and Baxi Platinum Combi ranges

Get experts tips every week from Baxi in the #TrainingTuesday video series

How to gain access to the Schrader valve on the expansion vessel

Top tip on how to gain access to the Schrader valve of the expansion vessel of the Baxi Duo-tec and Baxi Platinum Combi ranges

Get experts tips every week from Baxi in the #TrainingTuesday video series

How to remove the plate to plate heat exchanger 

Top tip on removing a plate to plate heat exchanger on a Baxi 600 Combi

Get experts tips every week from Baxi in the #TrainingTuesday video series

How to diagnose E117 fault on the EcoBlue Combi and EcoBlue Advance Combi

A simple check on how to diagnose E117 fault on a Baxi EcoBlue Combi and Baxi EcoBlue Advance Combi

Get experts tips every week from Baxi in the #TrainingTuesday video series

How to replace the diverter valve on Baxi Duo-tec and Platinum Combi

Top tip on replacing the diverter valve cartridge on the Baxi Duo-tec and Baxi Platinum Combi ranges

Get experts tips every week from Baxi in the #TrainingTuesday video series

How to keep the boiler cool during commissioning

Keeping the boiler cool during commissioning the Baxi Duo-tec and Baxi Platinum Combi ranges

Get experts tips every week from Baxi in the #TrainingTuesday video series

How to diagnose E133 lockout on the Baxi 600 Combi

A simple check on how to diagnose E133 lockout on the Baxi 600 Combi

Get experts tips every week from Baxi in the #TrainingTuesday video series

How to install the Baxi 600

Top tip to help you when you're installing the Baxi 600 Combi

Get experts tips every week from Baxi in the #TrainingTuesday video series

How to check the combustion box door seal on the Baxi Duo-tec and Platinum 

Checking the combustion box door seal on the Baxi Duo-tec and Baxi Platinum Combi ranges whilst servicing the boiler

Get experts tips every week from Baxi in the #TrainingTuesday video series

How to check if the pump is running without removing the case 

Top tip on how to check if the pump is running without taking the case off

Get experts tips every week from Baxi in the #TrainingTuesday video series

How to check for a primary flow switch fault

A simple check for identifying a primary flow switch fault on the Potterton Promax SL Heat only boiler

Get experts tips every week from Baxi in the #TrainingTuesday video series

Learn about de-aeration of the Baxi 600

Learn about the de-aeration of the heat exchanger on the Baxi 600 Combi

Get experts tips every week from Baxi in the #TrainingTuesday video series

Introducing the air pressure switch on the Baxi Duo-tec and Platinum Combi

Learn about the air pressure switch on the Baxi Duo-tec and Baxi Platinum Combi ranges